Daikin air-conditioning shop in Qingdao Distribution

Address The golden age of the building
Tel83200003
Fax83200003
Author Mr. Cao


Daikin VRV air-conditioning characteristics of the profile

Shanghai Daikin frequency central air-conditioning Freon is a direct evaporation of the central air-conditioning system is the world's newest and most advanced central air-conditioning system, it is a machine with a number of outdoor indoor machine (up to 32) component The. Has the following advantages:
1. Design a high degree of freedom:
Daikin VRV air-conditioned indoor frequency machine models have 9, 69 kinds of specifications, according to the requirements of construction and decoration of arbitrary choice, and a new wind is quite convenient, such as all-indoor heat exchanger or machine itself or air to draw a new market with A machine room for new fans can get all the new wind

2. Ceiling to save space:
VRV system is Freon tube directly into the evaporator, the refrigerant tubes very small and did not install the slope requirements, coupled with VRV indoor machines with a condensate pump, Condensing water can be forced to raise 500-1000mm, so the whole ceiling than a high degree of cold water Coil system to save 200-300mm.
3. No room:
VRV outdoor heat pump air-plane belonging to the outdoor machine can be placed on the roof or balcony can be greatly cut the engine room and an area of housing investment.
4. Advanced control:
VRV outdoor, indoor machine with a PC board, each of the machine room can be wired or wireless control of a separate, it can be stratified, area or building centralized control. Temperature control accuracy up to 0.5 ℃, and the realization of time, wind, wind direction, the state automatically set and control; indoor remote control planes can carry out self-test failure; such as the outdoor machines have Fault indoor automatically indicate that these machines have been attached to this Without having to buy another fault detection equipment (centrally controlled). This is the central air-conditioning water system second to none.
5. Energy conservation, low operating costs:
VRV is the most prominent advantage of energy to run a very low cost.
1) VRV systems need pumps, cooling towers, and other ancillary equipment. Design of electricity less than 20% of the water system.
2) As a result of the conversion compressors, outdoor power output based on indoor machines automatically adjust the size of the load, and the large units in the low-load operation when the relatively large energy-consuming. In that sense VRV system, saving about 30%.
6. At the same time, the supply of well-being:
VRV system based on functional requirements in different rooms at the same time to achieve the heating and cooling. May need, such as swimming pool heating, but also a restaurant without cooling, VRV can be used to achieve this particular request. Central air-conditioning and water systems to meet the requirements of this very difficult. VRV system in the winter temperature of -15 ℃ can work properly.
7. To run a long life:
Frequency VRV central air-conditioning imported Daikin of Japan, its major fault-free running time of 15 years, the life expectancy of 20 years; of the water system and central air-conditioning unit in terms of imports life of up to 15 years or so, but at the end of water system Equipment (fan-coil, etc.) generally only 5-8 years.
8. Reliable operation, easy maintenance, personnel management Needless to:
VRV quality and reliable equipment, running up almost no maintenance, management Needless to watch in person. Our one year warranty on the product for free, life-long service (only charge the cost of materials).
9. Extremely easy to install:
VRV-frequency central air-conditioning system is extremely easy to install. There are flat, layered, district, sub-installation, layered or regional delivery, installation of a short duration. Transformation of old buildings without affecting the normal office and business.
10. Convenient billing:
VRV system layered visual needs, district, sub-set households, accounting respectively for management and billing for rental.
11. Antifreeze winter without running:
VRV system due to water pipe, opened the winter holidays, free parking, central air-conditioning and water systems to pump 24 hours a day in winter can not be stopped, otherwise Central frozen pipes and equipment, waste a great deal of energy.


Daikin home central air-conditioning


Copyright© 2001-2012, qingdao-hotels. China Hotels Reservation all rights reserved.     link